The wire between combination meter connector D-03 (terminal 55) and M-ASTC-ECU connector E-121 (terminal 81)

NOTE:  Also check intermediate connector E-111 for loose, corroded, or damaged terminals, or terminals pushed back in the connector. If
intermediate connector E-111 is damaged, repair or replace the damaged component(s) as described in Harness Connector Inspection. If the
connector has been repaired or replaced, go to Step 9.

Q: Is the harness wire damaged?
YES: Repair it and then go to Step 9.
NO: Replace the combination meter and then go to Step 9.

STEP 5. Check the combination meter power supply circuit at combination meter harness connector D-03.

1. Disconnect combination meter connector D-03, and measure at the harness connector (component side). 
2. Turn the ignition switch to the "ON" position.