Montero V6-3.8L SOHC (2005)
depressing force and the hydraulic pressure.
Standard value
4. Perform the operation test with booster according to the following method. Turn the ignition switch to the "ON" position and measure the relation
between the brake pedal depressing force and the hydraulic pressure after pump motor was stopped.
Standard value
Brake Warning Light and Buzzer Operation Check
1. Chock the wheel and start the engine.
2. Hold the engine at the idling condition for more than 120 seconds.
CAUTION: Perform the check 120 seconds or more after turning the ignition switch to the "ON" position.
3. Release the parking brake and fully depress the brake pedal repeatedly 15 to 20 times in 10 seconds. Confirm that the warning light comes on and
the buzzer sounds.