Control Assembly: Service and Repair
Removal and Installation

HEATER CONTROL ASSEMBLY, A/C SWITCH AND INSIDE/OUTSIDE CHANGEOVER SWITCH

REMOVAL AND INSTALLATION

INSTALLATION SERVICE POINTS

>>A<< AIR OUTLET CHANGEOVER DAMPER LEVER CABLE INSTALLATION

1. Set the air outlet changeover control knob on the heater control assembly to the defroster position.
2. Set the air outlet changeover damper lever of the heater/cooler unit to the defroster position as shown in the illustration, and then connect the cable

to the link pin.

3. Push the outer cable in the direction of the arrow so that there is no looseness, and then secure it with the clip.
4. After installation, ensure that each damper operates smoothly by operating the heater control assembly knob

>>B<< AIR MIX DAMPER LEVER CABLE INSTALLATION

Control Assembly, HVAC|Removal and Installation|Page 5097 > < Condenser Fan Motor Relay, HVAC|Locations|Page 5092