1. Connect the special tool. Refer to "How to connect SWS monitor".  See: Reading and Clearing Diagnostic Trouble Codes/How to Connect SWS

Monitor

2. Connect SWS monitor kit MB991862 to the data link connector (13-pin).
3. Turn the ignition switch to the "LOCK" (OFF) position.
4. Operate scan tool MB991958 according to the procedure below to display "ECU COMM CHK."

1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "ECU COMM CHK."

5. Scan tool MB991958 should show "OK" on the "ECU COMM CHK" menu for the "ETACS ECU" menu. 

Q: Is "OK" displayed on the "ETACS ECU" menu?

YES: Go to Step 2.

NO: Refer to Inspection Procedure A-3 "Communication with ETACS-ECU is not possible."

STEP 2. Check the input signal (by using the pulse check mode of the monitor.)

Check the input signals from the transmitter.