Daytime Running Light Circuit

TECHNICAL DESCRIPTION (COMMENT) 
If the daytime running light function is not operating normally the daytime running light-ECU power circuit may be defective or the daytime running
light-ECU may be defective.

TROUBLESHOOTING HINTS

-

The daytime running light-ECU may be defective

-

The wiring harness or connectors may have loose, corroded, or damaged terminals, or terminals pushed back in the connector

DIAGNOSIS

Required Special Tools:

-

MB991223: Harness Set

-

MB991958: Scan Tool (MUT-III Sub Assembly)
-

MB991824: Vehicle Communication Interface (V.C.I.)

-

MB991827: MUT-III USB Cable

-

MB991911: MUT-III Main Harness B

-

MB991813: SWS Monitor Kit
-

MB991806: SWS Monitor Cartridge