1. Disconnect position light (RH) connector A-36 and measure the resistance available at the wiring harness side of the connector.

2. Measure the resistance value between terminal 1 and ground.

-

The resistance should equal 2 ohms or less.

Q: Is the measured resistance 2 ohms or less?

YES: Go to Step 21.

NO: Go to Step 20.

STEP 20. Check the wiring harness between position light (RH) connector A-36 (terminal 1) and ground.

Q: Is the wiring harness between position light (RH) connector A-36 (terminal 1) and ground in good condition?

YES: Replace the position light socket (RH). Verify that the position light (RH) illuminates normally.

NO: The wiring harness may be damaged or the connector(s) may have loose, corroded or damaged terminals, or terminals pushed back in the
connector. Repair the wiring harness as necessary. Verify that the position light (RH) illuminates normally.