mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2803 > < Initial Inspection and Diagnostic Overview|Page 2801
Page 344
background image

NO: Repair or replace the damaged component(s). Refer to Harness Connector Inspection. Verify that the fog lights illuminate normally.

STEP 10. Check the ground circuit to the fog light (RH). Test at fog light (RH) connector A-31.

1. Disconnect fog light (RH) connector A-31 and measure the resistance available at the wiring harness side of the connector.

2. Measure the resistance value between terminal 2 and ground.

-

The resistance should equal 2 ohms or less.

Q: Is the measured resistance 2 ohms or less?

YES: Go to Step 12.

NO: Go to Step 11.