Montero V6-3.8L SOHC (2005)
Ignition Coil: Testing and Inspection
Primary Coil and Ignition Power Transistor Continuity Check
PRIMARY COIL AND IGNITION POWER TRANSISTOR CONTINUITY CHECK
NOTE: An analog-type ohmmeter should be used.
NOTE: Connect the negative probe of the ohmmeter to terminal 1.
CAUTION: This test must be performed quickly (in less than 10 seconds) to prevent coil from burning and ignition power transistor from breaking.
1. Connect and disconnect 1.5 V battery between terminals 2 and 3, and observe the ohmmeter whether there is continuity or not.
2. If results do not agree with the table shown, replace the primary coil and ignition power transistor assembly.