Air Flow Meter/Sensor: Oscilloscope Patterns and Waveforms

Wave Pattern Inspection Using an Analyzer 

Measurement method

(1) Disconnect the volume air flow sensor connector, and connect the special tool (test harness: MB991348) in between. (All terminals should be

connected.)

(2) Connect the analyzer special patterns pickup to terminal (3) of the volume air flow sensor connector.

Alternative method (when test harness is not available)

Connect the analyzer special patterns pickup to ECM terminal (90).

Standard wave pattern

Observation conditions

Wave Pattern

Observation conditions

Observation conditions (Pattern changes with engine speed changes)

Wave pattern observation points:

Check that cycle time T becomes shorter and the frequency increases when the engine speed is increased.

Examples of abnormal wave patterns

-

Example 1
Cause of problem