mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Barometric Pressure Sensor > < Component Tests and General Diagnostics
Page 1
background image

Air Flow Meter/Sensor: Oscilloscope Patterns and Waveforms

Wave Pattern Inspection Using an Analyzer Measurement Method

1. Disconnect the volume air flow sensor connector, and connect the special tool (test harness: MB991348) in between. (All terminals should be

connected.) 

2. Connect the analyzer special patterns pickup to terminal (3) of the volume air flow sensor connector.

Note:  Alternative method of connection (when test harness is not available): connect the analyzer special patterns pickup to ECM terminal (70).

Standard wave pattern

Wave pattern observation points: check that cycle time T becomes shorter and the frequency increases when the engine speed is increased.
Observation conditions: Engine idling at 700 rpm (Pattern changes with engine speed changes)

EXAMPLES OF ABNORMAL WAVE PATTERNS

Example 1
-

Cause of problem: malfunction of sensor interface
-

Wave pattern characteristics: rectangular wave pattern is output even when the engine is not started.

Example 2
-

Cause of problem: damaged rectifier or vortex generation column
-

Wave pattern characteristics: Unstable wave pattern with non-uniform frequency. However, when an ignition leak occurs during
acceleration, the wave pattern will be distorted temporarily, even if the volume air flow sensor is normal.