Ignition Control Module: Testing and Inspection

NOTE:  An analog-type circuit tester should be used.

Ignition Power Transistor

Ignition Power Transistor Continuity Table

No. 1 - No. 4 Coil Side

1. Connect the negative (-) terminal of the 1.5 V power supply to terminal (4) of the ignition power transistor; then check whether there is continuity

between terminal (13) and terminal (4) when terminal (3) and the positive (+) terminal are connected and disconnected.

NOTE:  Connect the (-) probe of the circuit tester to terminal (13).

2. Replace the ignition power transistor if there is a malfunction.

Ignition Power Transistor

Ignition Power Transistor Continuity Table

No. 2 - No. 5 Coil Side

1. Connect the negative (-) terminal of the 1.5 V power supply to terminal (4) of the ignition power transistor; then check whether there is continuity

between terminal (12) and terminal (4) when terminal (2) and the positive (+) terminal are connected and disconnected.

NOTE:  Connect the (-) probe of the circuit tester to terminal (12).

2. Replace the ignition power transistor if there is a malfunction.