mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Idle Air Control Motor (Stepper Motor) Check|Page 1585 > < Idle Air Control Motor (Stepper Motor) Check|Page 1583
Page 2
background image

1. Connect the oscilloscope probe to PCM terminals No. 14, No. 15, No. 28 and No. 29.

Wave Pattern Observation Points

1. Check that the standard wave pattern appears when the idle air control motor is operating.

Point A:Presence or absence of induced electromotive force from the motor turning. (Refer to abnormal wave pattern.)

point B: Height of coil back electromotive force

Examples of Abnormal Wave Patterns 

Example 1

Cause of problem

-

Malfunction of motor. (Motor is not operating.) 

Wave pattern characteristics

Idle Air Control Motor (Stepper Motor) Check|Page 1585 > < Idle Air Control Motor (Stepper Motor) Check|Page 1583