Intake Air Temperature Sensor: Testing and Inspection

INTAKE AIR TEMPERATURE SENSOR CHECK

1. Disconnect the volume airflow sensor connectors.

2. Measure resistance between terminals No. 5 and No. 6.

Standard value:

13 - 17 kOhms [at -20 °C (-4 °F)] 
5.3 - 6.7 kOhms [at 0 °C (32 °F)] 
2.3 - 3.0 kOhms [at 20 °C (68 °F)] 
1.0 - 1.5 kOhms [at 40 °C (104 °F)] 
0.56 - 0.76 kOhms [at 60 °C (140 °F)] 
0.30 - 0.42 kOhms [at 80 °C (176 °F)]

3. If not within specifications, replace the volume airflow sensor.

4. Measure resistance while heating the sensor using a hair dryer.

5. If resistance does not decrease as heat increases, replace the volume airflow sensor assembly.