Blower Motor: Service and Repair

INSTALLATION SERVICE POINT

A Inside/Outside Air Changeover Damper Cable Installation

1. Set the inside/outside air changeover control knob on the heater control assembly to the outside air induction position.
2. Set the inside/outside air changeover damper link of the blower assembly to the outside air induction position as shown in the illustration, and then

connect the cable to the link pin.

3. Push the outer cable in the direction of the arrow so that there is no looseness, and then secure it with clip.