Refrigerant: Service and Repair
Charging A/C System

1. With the handles turned in all the way (valve closed), install the adaptor valve to the low-pressure side of the gauge manifold.
2. Connect the charging hose (blue) to the adaptor valve.
3. Connect the quick joint (for low-pressure) to the charging hose (blue).

CAUTION:  Use tools that are suited to R-134a.

CAUTION:  To install the quick joint, press section "A" firmly against the service valve until a click is heard. When connecting, run your hand
along the hose while pressing to ensure that there are no bends in the hose.

4. Connect the quick joint (for low-pressure) to the low- pressure service valve.

NOTE:  The low-pressure service valve should be connected to the suction hose.

5. Close the high and low-pressure valves of the gauge manifold.
6. Install the vacuum pump adaptor to the vacuum pump.
7. Connect the vacuum pump plug to the vacuum pump adaptor.
8. Connect the charging hose (yellow) to the R-134a connection port of the vacuum pump adaptor.
9. Tighten the adaptor valve handle (valve open).

10. Open the low-pressure valve of the gauge manifold.
11. Turn the power switch of the vacuum pump to the "ON" position.

NOTE:  Even if .the vacuum pump power switch is turned ON, the vacuum pump will not operate because of the power supply connection in
step(7).