background image

-

The current should be 0.5 ampere or more.

(4) Turn the ignitor switch "OFF."

-

If within specifications, go to Step 5.

-

If not within specifications, check the harness wire and connector between the combination meter and the ignition switch, and repair or
replace. Then confirm that the malfunction symptom is eliminated.

STEP 5. Check the harness wire between the combination meter connector C-04 and the ECM connector C-50.

NOTE: After inspecting the intermediate connector C-16, inspect the wire. 

-

If the intermediate connector C- 16 is damaged, repair or r9place it. Then confirm That the malfunction symptom is eliminated.

-

If the wire between the combination meter connector C-04 and the ECM connector C-50 is damaged, repair it.

-

If the wire between the combination meter connector C-04 and the ECM connector C-50 is damaged, repair or replace the combination meter
connector C-04.

-

Then confirm that the malfunction symptom is eliminated.

STEP 6. Check harness connector C-50 at the ECM for damage.

-

If harness connector C-50 is damaged, repair or replace it.

-

If harness connector C-50 is in good condition, replace the ECM. Then confirm that the malfunction symptom is eliminated.