CAUTION: To prevent damage to the scan tool, turn the ignition switch "OFF" before connecting or disconnecting the scan tool.

-

If DTC is not output, go to Step 2.

-

If DTC is output, refer to Inspection Chart for Diagnostic Trouble Codes.

STEP 2. Check the circuit at the combination meter connector C-04.

(1) Disconnect connector C-04 and measure at the harness side.

(2) Disconnect the ECM connector C-50.

(3) Check for continuity between connector C-04 terminal 23 and ground.

-

There should be no continuity.

(4) If there is continuity repair the harness wire between the combination meter connector C-04 and the ECM connector C-50.
(5) If there is no continuity, replace the ECM. Then confirm that the malfunction symptom is eliminated.