Montero Sport LS 2WD V6-3.0L SOHC (1998)
2. Measure resistance between terminal 2 (white clip of the special tool) and either terminal 1 (red clip) or terminal 3 (blue clip) of the connector
at the idle air control motor side.
Standard value: 28 - 33 ohms [at 20°C (68°F)]
-
If resistance is not within the standard value, replace the IAC motor.
3. Measure the resistance between terminal 5 (green clip of the special tool) and either terminal 6 (yellow clip) or terminal 4 (black clip) of the
connector at the idle air control motor side.
Standard value: 28 - 33 ohms [at 20°|C (68°F)]
-
If resistance is not within the standard value, replace the IAC motor.