Keyless Entry Module: Adjustments

ETACS-ECU FUNCTION ADJUSTMENT PROCEDURE

The following functions can be adjusted by operating input swatches. The adjustments will be stored in the ECU memory even after a battery cable is
disconnected:

1. Entry conditions the adjustment mode

The ETACS-ECU sounds a tone alarm once when all of the following conditions are satisfied, and then enters the adjustment mode:
-

Data link control: "ON" (Connect scan tool MB991502 or ground the data link connector No.1 terminal.)

2. Exit conditions from the adjustment mode

The ETACS-ECU cancels the adjustment mode when any of the following conditions is satisfied:
-

Diagnosis control: "OFF" (Disconnect scan tool MB991502 or disconnect the data link connector No.1 terminal from the ground.)

-

Key reminder switch: "ON" (Pull out the ignition key.)

3. Adjustment of functions

-

Switching of keyless entry answerback function. (From activation to deactivation, or vice versa)

-

Initialization the above function (From deactivation to activation)

-

Key reminder switch: "OFF"

-

Ignition switch: "OFF"

-

Door switch: "OFF" (Close the door.)

-

If all of the conditions above are satisfied, the taillight switch will be turned on for more than 10 seconds.

-

Ignition switch: Other than "OFF"

-

Door switch: "ON" (Open the door.)

-

After the ETACS-ECU has entered the adjustment mode, no adjustment is made within 3 minutes (If any adjustment is made within 3 minutes
, the ETACS-ECU monitors a adjustment operation for other 3 minutes.)

-

Other warning tone alarm sounds