mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Shifter A/T > < Electrical Specifications|Page 3173
Page 1
background image

Shift Solenoid: Testing and Inspection

SHIFT SOLENOID NO.1 CHECK 

1. Disconnect the shift solenoid connector and measure at the sensor side.
2. Measure the resistance between terminal 6 and ground.

Standard value: 11 - 15 ohms [at 25°C (77°F)] 

3. If the resistance is not within the standard value, replace the solenoid assembly.

SHIFT SOLENOID NO.2 CHECK 

1. Disconnect the shift solenoid connector and measure at the sensor side.
2. Measure the resistance between terminal 7 and ground.

Standard value: 11 - 15 ohms [at 25°C (77°F)] 

3. If the resistance is not within the standard value, replace the solenoid assembly.

Shifter A/T > < Electrical Specifications|Page 3173