mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Actuators and Solenoids - Differential > < Electrical Specifications|Page 3898
Page 1
background image

Torque Converter Clutch Solenoid: Testing and Inspection

LOCK-UP SOLENOID CHECK 

1. Disconnect the shift solenoid connector and measure at the sensor side.
2. Measure the resistance between terminal 8 and ground.

Standard value: 11 - 15 ohms [at 25°C (77°F)] 

3. If the resistance is not within the standard value, replace the solenoid assembly.

Actuators and Solenoids - Differential > < Electrical Specifications|Page 3898