Generator: Testing and Inspection

INSPECTION
ROTOR CHECK

Rotor

1. Check the continuity between the slip rings of the field coil. If the resistance value is not within the standard value, replace the rotor.

Standard value: approximately 2 - 5 Ohm

Rotor

2. Check the continuity between the slip ring and the core. If there is continuity, replace the rotor.

STATOR CHECK

Stator

1. Check the continuity between the coil lead. If there is no continuity, replace the stator.

Stator

2. Check the continuity between the coil and the core. If there is continuity, replace the stator.

Electrical Specifications|Page 3886 > < Electrical Specifications|Page 3884