13.

Install the A/T breather hose into the new A/T breather assembly (hose cover). The cut end should face the installation side of the new A/T
breather assembly (hose cover).

14.

Use the new joint tube to connect the new extension hose to the transfer breather hose. The transfer breather hose must be inserted into the joint
tube at least 15 mm (0.6 inch) and the hose clamps properly located.

! CAUTION

Position the transfer breather hose between the transmission and the A/T breather hose.

Secure the transfer breather hose, using the hose using clamp provided in the repair kit.