DIAGNOSIS

Check that the calibration of the compass can be carried out at another place.

1. Move the vehicle to be checked to another place. 

NOTE:  Move to a wide flat place where calibration of the compass can be carried out.

2. Check again that calibration of the compass can be carried out.

NOTE:  If the calibration is correct, the following causes can be assumed.

-

Calibration is difficult due to the magnet direction and direction of the vehicle at the start of calibration.

-

There is a disturbing magnetic field in the area, and calibration is difficult.

If the calibration is correct, check that the malfunction is eliminated.

If the calibration is incorrect, replace the inside rear view mirror (with compass and temperature display). Then, check that the malfunction is eliminated.

04 - Inspection Procedure

There Is A Discrepancy Between the Actual Outside Temperature and Displayed Temperature or an Error Displays (CS, OS)

Outside Temperature Meter Electronic Compass Circuit

CIRCUIT OPERATION

-

A thermistor is used for the thermo sensor. The resistance value fluctuate according to ambient temperature. The inside rear view mirror (with 
compass and temperature display) calculates outside temperature according to the changes in this resistance value, and displays it on the inside
rear view mirror (with compass and temperature display).

TECHNICAL DESCRIPTION (COMMENT)

The outside thermo sensor, inside rear view mirror (with compass and temperature display) harness, or connector may be defective.

TROUBLESHOOTING HINTS

-

Malfunction of the outside thermo sensor

-

Malfunction of the inside rear view mirror (with compass and temperature display)

-

Damaged harness or connector

DIAGNOSIS

STEP 1. Check the outside thermo sensor internal resistance.

1. Remove the outside thermo sensor. 
2. Check the internal resistance of the outside thermo sensor are at the standard values at temperature of 20 °C (68 °F) and 40 °C (104 °F).

Standard value:
Approximately 1,200 ohm [at 20 °C (68 °F)]
Approximately 500 ohm [at 40 °C (104 °F)]

Q: Does the out side thermo sensor resistance meet standard values above?

YES: Go to Step 3.
NO: Go to Step 2.