EVACUATING REFRIGERANT

1. With the handles turned back all the way (valve closed), install the adaptor valve to the low-pressure side of the gauge manifold.
2. Connect the charging hose (blue) to the adaptor valve.
3. Connect the quick joint (for low pressure) to the charging hose (blue).
4. Connect the quick joint (for low pressure) to the low pressure service valve.

NOTE:  The low-pressure service valve should be connected to the low pressure hose.

CAUTION:  Use tools that are designed for R-134a.

Handling Tubing and Fittings|Page 995 > < Handling Tubing and Fittings|Page 993