mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Oscilloscope Check|Page 2138 > < Oscilloscope Check|Page 2136
Page 3
background image

Example 1

Cause of problem

-

Malfunction of motor. (Motor is not operating.)

Wave pattern characteristics

-

Induced electromotive force from the motor turning does not appear.

Example 2

Cause of problem

-

Open circuit in the line between the idle air control motor and the PCM.

Wave pattern characteristics

-

Current is not supplied to the motor coil on the open circuit side. (Voltage does not drop to 0 volt.) Furthermore, the induced electromotive force
wave pattern at the normal side is slightly different from the normal wave pattern.

Oscilloscope Check|Page 2138 > < Oscilloscope Check|Page 2136