mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 2789 > < Component Tests and General Diagnostics
Page 2
background image

1. Remove the throttle body.
2. Remove the idle air control motor.
3. Connect special tool MB991709 to the idle air control motor connector.

4. Connect the positive terminal of a power supply (approximately 6 V) to terminal 2 and the terminal 5.
5. Connect the negative terminal of the power supply to each clip as described in the following steps. Then check whether or not the stepper motor

vibrates slightly as it operates.
1. Connect the negative terminal of the power supply to terminal 1 and terminal 4.
2. Connect the negative terminal of the power supply to terminal 3 and terminal 4.
3. Connect the negative terminal of the power supply to terminal 3 and terminal 6.
4. Connect the negative terminal of the power supply to terminal 1 and terminal 6.
5. Connect the negative terminal of the power supply to terminal 1 and terminal 4.
6. Repeat the tests in sequence from (5) to (1) to test opposite movement of the IAC.

6. If vibration is detected during the test, the stepper motor can be considered to be normal.

Component Tests and General Diagnostics|Page 2789 > < Component Tests and General Diagnostics