mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Main Relay (Computer/Fuel System) > < Component Tests and General Diagnostics|Page 2789
Page 2
background image

Wave Pattern Observation Points

1. Check that the standard wave pattern appears when the idle air control motor is operating.

Point A: Presence or absence of induced electromotive force from the motor turning. (Refer to abnormal wave pattern.)

Point B: Height of coil back electromotive force

Examples of Abnormal Wave Patterns

Example 1

Cause of problem

-

Malfunction of motor. (Motor is not operating.) 

Wave pattern characteristics

-

Induced electromotive force from the motor turning does not appear.

Example 2

Cause of problem

-

Open circuit in the line between the idle air control motor and the PCM.

Wave pattern characteristics

-

Current is not supplied to the motor coil on the open circuit side. (Voltage does not drop to 0 volt.) 
Furthermore, the induced electromotive force wave pattern at the normal side is slightly different from the normal wave pattern.