Montero Sport XS 2WD V6-3.5L SOHC (2001)
Rotor: Testing and Inspection
Rotor
1. Check the continuity between the slip rings of the field coil. If the resistance value is not within the standard value, replace the rotor:
Standard value: approximately 2 - 5 Ohms
Rotor
2. Check the continuity between the slip ring and the core. If there is continuity, replace the rotor.