mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Refrigerant Leak Repair|Page 5771 > < Refrigerant Leak Repair
Page 1
background image

Refrigerant: Service and Repair
Charging, Recovery and Refilling Oil

1. With the handles turned in all the way (valves closed), install the adaptor valve to the low-pressure side of the gage manifold.
2. Connect the charging hose (blue) to the adaptor valve.
3. Connect the quick joint (for low pressure) to the charging hose (blue).
4. Connect the quick joint (for low pressure) to the low pressure service valve.

NOTE:  The low-pressure service valve should be connected to the compressor.

CAUTION:
1. Use tools that are designed for R-134a.
2. To connect the quick joint, press section A firmly against the service valve until a click is heard. When connecting, run your hand along the

hose while pressing to ensure that there are no bends in the hose.

5. Close the high and low pressure valves of the gage manifold.
6. Install the vacuum pump adaptor to the vacuum pump.
7. Connect the vacuum pump plug to the vacuum pump adaptor.
8. Connect the charging hose (yellow) to the R-134a connection port of the vacuum pump adaptor.
9. Tighten the adaptor valve handle (valve open).

10. Open the low pressure valve of the gage manifold.
11. Turn the power switch of the vacuum pump to the ON position.

NOTE:  Even if the vacuum pump power switch is turned on, the vacuum pump will not operate because of the power supply connection in step
(7).