mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Refrigerant Leak Repair|Page 5773 > < Refrigerant Leak Repair|Page 5771
Page 3
background image

21. Start the engine.
22. Operate the air conditioning and set it to the lowest temperature (MAX. COOL).
23. Fix the engine speed at 1,500 r/min.
24. Tighten the handle of the adaptor valve (valve open) to charge the required volume of refrigerant.

CAUTION:  If the bulk container is inverted, liquid refrigerant may be drawn into the compressor, damaging it by hydraulic lock. Keep the bulk
container upright to ensure that refrigerant is charged in gas state.

25. After charging with refrigerant, turn the handle of the adaptor valve back all the way (valve closed).
26. Tighten the charge valve handle (valved closed). Disconnect the quick joint (for low pressure) from the low-pressure service valve.

CORRECTING LOW REFRIGERANT LEVEL WHEN THE BULK CONTAINER IS USED

1. Install the adaptor valve with the handle turned all the way in (valve closed) to the charge valve.
2. Connect the charging hose (blue) to the adaptor valve.
3. Connect the charging hose (blue) to the quick joint (for low pressure).
4. Open the valve of the bulk container.
5. Turn the handle of the adaptor valve to bleed the air.

6. Connect the quick joint (for low pressure) to the low pressure service valve.

NOTE:  The low-pressure service valve should be connected to the compressor.

7. Start the engine.
8. Operate the air conditioning and set it to the lowest temperature (MAX. COOL).
9. Fix the engine speed at 1,500 r/min.

10. Tighten the handle of the adaptor valve (valve open) and replenish refrigerant while checking the quantity through the sight glass.

CAUTION:  If the bulk container is inverted, liquid refrigerant may be draw into the compressor, damaging it by hydraulic lock. Keep the bulk
container upright to ensure that refrigerant is charged in gas state.

11. After replenishing is completed, turn the handle of the adaptor valve all the way in (valve closed) and disconnect the quick joint.

METHOD USING A REFRIGERANT RECOVERY AND RECYCLING UNIT

Use the refrigerant recovery and recycling unit to refill with refrigerant.

Refrigerant Leak Repair|Page 5773 > < Refrigerant Leak Repair|Page 5771