mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 484 > < Component Tests and General Diagnostics|Page 482
Page 1
background image

Air Flow Meter/Sensor: Oscilloscope Patterns and Waveforms

Wave Pattern Inspection Using an Analyzer  
Measurement method 

(1) Disconnect the volume air flow sensor connector, and connect the special tool (test harness: MB991348) in between. (All terminals should be

connected.)

(2) Connect the analyzer special patterns pickup to terminal.
(3) of the volume air flow sensor connector.

Alternative method (when test harness is not available)  

Connect the analyzer special patterns pickup to ECM terminal (90).

Standard wave pattern Observation Conditions 

Standard wave pattern 

Observation conditions (Pattern changes with engine speed changes) 

Wave pattern observation points 

Check that cycle time T becomes shorter and the frequency increases when the engine speed is increased.