mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Lock-Up Solenoid|Page 3790 > < Shift Solenoid, A/T|Specifications
Page 1
background image

Shift Solenoid: Testing and Inspection
Lock-Up Solenoid

INSPECTION

1. Disconnect the lock-up solenoid connector.
2. Measure the resistance between terminal No. 8 and the ground.

Standard value: 13 +/- 2 ohms [at 25° C (77° F)]

3. If the resistance is outside the standard value, replace the solenoid assembly.

Lock-Up Solenoid|Page 3790 > < Shift Solenoid, A/T|Specifications