Shift Solenoid: Testing and Inspection
Shift Solenoid No. 1

INSPECTION

1. Disconnect the shift solenoid connector.
2. Measure the resistance between terminal No. 6 and the ground.

Standard value: 13 +/- 2 ohms [at 25° C (77° F)]

3. If the resistance is outside the standard value, replace the solenoid assembly.