Hydraulic Brake Booster: Pinout Values and Diagnostic Parameters

TERMINAL VOLTAGE CHECK CHART 

NOTE:  
-

Two ECUs of the same type are located inside the floor console. The upper ECU is the ABS-ECU to which a blue connector is connected. The
lower ECU is the transfer ECU to which a green connector is connected.

-

Do not measure terminal voltage during the approximately three seconds after the ignition switch is turned "ON. " The ABS-ECU performs the
initial check during that period.

1. Measure the voltages between terminal (12), (25), (26) or (42) (ground terminals) and each respective terminal.