mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Mechanical Specifications|Page 1594 > < Mechanical Specifications|Page 1592
Page 1
background image

Thermostat: Service and Repair

REMOVAL AND INSTALLATION 

REMOVAL SERVICE POINT 

<<A>> RADIATOR LOWER HOSE DISCONNECTION 
After making mating marks on the radiator hose and the hose clamp, disconnect the radiator hose.

INSTALLATION SERVICE POINT 

>>A<< RADIATOR LOWER HOSE CONNECTION 
1. Insert each hose as far as the projection of the water inlet fitting.
2. Align the mating marks on the radiator hose and hose clamp, and then connect the radiator hose.

INSPECTION 

THERMOSTAT CHECK 

1. Immerse the thermostat in water, and heat the water while stirring. Check the thermostat valve opening temperature. 

Standard value:
Valve opening temperature: 88 ± 2°C (190 ± 36°F) 

Mechanical Specifications|Page 1594 > < Mechanical Specifications|Page 1592