mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2153 > < Initial Inspection and Diagnostic Overview|Page 2151
Page 123
background image

1. Connect scan tool MB991502 to the data link connector.
2. Check that the tone alarm of scan tool MB991502 sounds when the input signal enters.

Q: Does the tone alarm of scan tool MB991502 sound when the input signal enters?

YES: Replace the front-ECU. The passing switch should work normally.
NO: Check the passing switch input circuit. Refer to Inspection Procedure Q-14.

STEP 3. Check the input signal (by using a voltmeter). Check the input signal from the passing switch.

1. Use special tool MB991529 to connect a voltmeter between ground terminal 4 or 5 and ETACS-ECU terminal 9 of the data link connector.
2. Check that the voltmeter indicator deflects once when the input signal enters.

Q: Does the voltmeter indicator deflect?

YES: Replace the front-ECU. The passing switch should work normally.
NO: Check the passing switch input circuit. Refer to Inspection Procedure Q-14.

Inspection Procedure L-5

Headlight, taillight: Headlight automatic shutdown function does not work normally

TECHNICAL DESCRIPTION (COMMENT)

The ETACS-ECU operates the headlight automatic shutdown function, based on the signals from the following switches:

-

Ignition switch (IG1)

-

Driver's door switch

-

Taillight switch

-

Headlight switch

If the function does work normally, a defect on relevant input circuits, the ETACS-ECU or the front-ECU is suspected.

TROUBLESHOOTING HINTS

-

Malfunction of the driver's door switch

-

Malfunction of the column switch (turn-signal light and lighting switch)

-

Malfunction of the ETACS-ECU

-

Malfunction of the front-ECU

-

Damaged harness wires or connectors

DIAGNOSIS

Required Special Tools:

-

MB991223: Test Harness Set

-

MB991502: Scan Tool (MUT-II)

-

MB991529: Diagnostic Trouble Code Check Harness

STEP 1. Check the DTC.

Q: Does the DTC set when the ignition switch is turned to the "LOCK" (OFF) position?

YES: Carry out the troubleshooting by referring to Diagnostic Trouble Code Chart.
NO: Go to Step 2 <when using scan tool MB991502> or 3 <when using a voltmeter>.

STEP 2. Check the input signal (by using scan tool MB991502).

Initial Inspection and Diagnostic Overview|Page 2153 > < Initial Inspection and Diagnostic Overview|Page 2151