Simplified Wiring System: Adjustments

ADJUSTMENT PROCEDURES OF SWS FUNCTION

Required Special Tools:

-

MB991223: Test Harness Set

-

MB991502: Scan Tool (MUT-II)

-

MB991529: Diagnostic Trouble Code. Check Harness

Through special operation of input switches, it is possible to disable and enable the functions listed below. Settings are retained even if the battery is
disconnected.

-

Keyless entry hazard answerback function

-

Headlight automatic shutdown function

-

Initialization of above mentioned functions

NOTE:  The keyless entry hazard answerback can also be adjusted by operating the RKE transmitter. (The operating method using the transmitter is
easier.) Refer to Keyless Entry System - On-vehicle Service - Enabling/Disabling the Answerback Function.

Configuration Mode Entry Conditions

1. Set each switch at the following condition.

-

Hazard warning light switch: OFF

-

Diagnosis control: ON (scan tool MB991502 connected or terminal 1 of data link connector connected to earth)

-

Key reminder switch: OFF (ignition key inserted)

-

Ignition switch: "LOCK" (OFF)

-

Driver's door switch: OFF (driver's door closed)

2. When the windshield washer switch is continuously turned ON for more than 10 seconds, the tone alarm integrated in the ETACS-ECU sounds

once and the mode is switched to the configuration mode.

Configuration Mode Cancellation Conditions

The ETACS-ECU cancels the configuration mode when any of the conditions listed below is satisfied.

-

Diagnosis control: OFF (scan tool MB991502 disconnected or terminal 1 of data link connector disconnected from earth)

-

Key reminder switch: OFF (ignition key removed)

-

Ignition switch: any position other than "LOCK" (OFF)

-

Driver's door switch: ON (driver's door open)

-

No configuration performed within three minutes of entry to configuration mode (If configuration is performed within first three minutes,
monitoring continues for three minutes from that point.)

-

Any other warning tone alarm output occurs