Ventilation Switch: Service and Repair

HEATER CONTROL ASSEMBLY, A/C SWITCH AND INSIDE/OUTSIDE CHANGEOVER SWITCH

REMOVAL AND INSTALLATION

Pre-removal and Post-installation Operation

-

Front Drivers Side Under Cover Removal and Installation 

-

Floor Console Removal and Installation 

-

Foot Duct C and Foot Duct D Removal and Installation

INSTALLATION SERVICE POINT

>>A<< AIR OUTLET CHANGEOVER DAMPER LEVER CABLE INSTALLATION

1. Set the air outlet changeover control knob on the heater control assembly to the defroster position.

2. Set the air outlet changeover damper lever of the heater/cooler unit to the defroster position as shown in the illustration, and then connect the cable

to the link pin.

3. Push the outer cable in the direction of the arrow so that there is no looseness, and then secure it with the clip.
4. After installation, ensure that each damper operates smoothly by operating the heater control assembly knob.

>>B<< AIR MIX DAMPER LEVER CABLE INSTALLATION

1. Set the temperature control knob on the heater control assembly to the maximum hot position.
2. Set the air mix damper lever of the heater/cooler unit to the maximum hot position as shown in the illustration, and then connect the cable to the

lever pin.