Montero XLS 4WD V6-3.5L SOHC (2001)
Loosen the bolt shown in the diagram.
INSTALLATION SERVICE POINTS
<<A>> DIFFERENTIAL MOUNTING INSULATOR BOLT TIGHTENING
Place the vehicle on the ground after temporarily tightening bolts to prevent bushing from twisting, then fully tighten the bolts in the unladen
condition. Tighten the bolts shown in the diagram to the specified torque in the order of A, B, C, D or A, C, B, D.
Specified torque: 69 ± 9 Nm (51 ± 7 ft. lbs.)
>>B<< INNER SHAFT INSTALLATION
Be careful not to damage the lip of the dust seal and oil seal.