Outlander 2WD V6-3.0L (6B31) (2007)
INSTALLATION SERVICE POINT
>>A<< GENERATOR ASSEMBLY INSTALLATION
1. Temporarily tighten the generator to the generator bracket.
2. In accordance with the tightening order shown in the illustration, tighten the installation bolts for the generator bracket to the specified torque.
Tightening torque: 47 ± 11 N.m (35 ± 8 ft-lb)