Thermostat: Testing and Inspection

THERMO VALVE CHECK

1. Obtain a container filled with water and place the thermo valve in it with a stick (approximately 6 mm in diameter) inserted. Gradually warm up

the water while stirring, and check that the thermo valve opening temperature is within the standard value. The stick rises when the thermo valve
opens.

Standard value: 75 ± 1.5°C (167 ± 34.7°F)

2. Warm up the water to the full-open temperature of the thermo valve, and check that the valve lift amount is within the standard value.

Standard value: Full-open temperature 88°C (190°F)
Valve lift amount when it is fully opened:
 3 mm or higher

NOTE: Measure the height of the fully closed valve in advance, and then measure the valve height at fully open temperature to calculate the lift
amount.

Torque Converter > < Shift Linkage, A/T|Service and Repair|Page 3973