Pickup 2WD L4-2.0L SOHC (1983)
Thermostatic Air Cleaner: Specifications
Vacuum Specifications
Vacuum required to open Thermostatic Air Cleaner Valve ......................................................................................................................... 25 kPa (8 in. Hg)
Vacuum required to open Vacuum Switching Valve ................................................................................................................................. 34 kPa (10 in. Hg)