Condenser Fan Motor Relay: Testing and Inspection

Fig. 39  Condenser Fan Motor Relay Inspection

1. Connect an ohmmeter as shown in Fig. 39. No continuity should exist between terminals L and B.
2. Apply battery voltage between terminals S1 and S2; continuity should now exist between terminals L and B.