mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Keyless Entry > < Alarm System Transponder|Description and Operation
Page 1
background image

Alarm System Transponder: Service and Repair

The Sentry Key Immobilizer System (SKIS) must be initialized following a Sentry Key REmote Entry Module (SKREEM) replacement. SKIS
initialization requires the use of a diagnostic scan tool. Initialization will also require that you have access to the unique four-digit PIN code that was
assigned to the original SKREEM. The PIN code must be used to enter the Secured Access Mode in the SKREEM. This PIN number may be obtained
from the vehicle owner, from the original vehicle invoice, or from the MMNA Warranty Super Screen.

NOTE:  If a Powertrain Control Module (PCM) is replaced on a vehicle equipped with the Sentry Key Immobilizer System (SKIS), the unique Secret
Key data must be transferred from the Sentry Key REmote Entry Module (SKREEM) to the new PCM using the PCM replacement procedure. This
procedure also requires the use of a diagnostic scan tool and the unique four-digit PIN code to enter the Secured Access Mode in the SKREEM. Refer to
the appropriate diagnostic information for the proper PCM replacement procedures.

SENTRY KEY TRANSPONDER PROGRAMMING

All Sentry Keys included with the vehicle are pre-programmed to work with the Sentry Key Immobilizer System (SKIS) when it is shipped from the
factory. The Sentry Key REmote Entry Module (SKREEM) can be programmed to recognize up to a total of eight Sentry Keys. When programming a
blank Sentry Key transponder, the key must first be cut to match the ignition switch lock cylinder in the vehicle for which it will be used. Once the
additional or new key has been cut, the SKREEM must be programmed to recognize it as a valid key. There are two possible methods to program the
SKREEM to recognize a new or additional valid key, the Secured Access Method and the Customer Learn Method. Following are the details of these
two programming methods.

SECURED ACCESS METHOD

The Secured Access method applies to all vehicles. This method requires the use of a diagnostic scan tool. This method will also require that you have
access to the unique four-digit PIN code that was assigned to the original SKREEM. The PIN code must be used to enter the Secured Access Mode in
the SKREEM. This PIN number may be obtained from the vehicle owner, from the original vehicle invoice, or from the Mitsubishi Customer Center.

CUSTOMER LEARN METHOD

NOTE:  The Customer Learn feature is only available on domestic vehicles, or those vehicles which have a U. country code designator. This
programming method also requires access to at least two valid Sentry Keys. If two valid Sentry Keys are not available, or if the vehicle does not have a
U.. country code designator, the Secured Access Method MUST be used to program new or additional valid keys to the SKREEM.

The Customer Learn programming method procedures are as follows:

1. Obtain the blank Sentry Key(s) that are to be programmed as valid keys for the vehicle. Cut the blank key(s) to match the ignition switch lock

cylinder mechanical key codes.

2. Insert one of the two valid Sentry Keys into the ignition switch and turn the ignition switch to the ON position.
3. After the ignition switch has been in the ON position for longer than three seconds, but no more than fifteen seconds, cycle the ignition switch

back to the OFF position. Replace the first valid Sentry Key in the ignition switch lock cylinder with the second valid Sentry Key and turn the
ignition switch back to the ON position. The second valid Sentry Key must be inserted in the lock cylinder within fifteen seconds of removing the
first valid key.

4. About ten seconds after the completion of the security indicator in the instrument cluster will start to flash to indicate that the system has entered

the Customer Learn programming mode.

5. Within sixty seconds of entering the Customer Learn programming mode, turn the ignition switch to the OFF position, replace the valid Sentry

Key with a blank Sentry Key transponder, and turn the ignition switch back to the ON position.

6. About ten seconds after the completion of the security indicator will stop flashing, stay on solid for three seconds, then turn off to indicate that

the blank Sentry Key has been successfully programmed. The SKIS will immediately exit the Customer Learn programming mode. After the
ignition is cycled the vehicle may be started using the newly programmed valid Sentry Key.

Each of these steps must be repeated and completed in their entirety for each additional Sentry Key that is to be programmed. If the above steps are not
completed in the given sequence, or within the allotted time, the SKREEM will exit the Customer Learn programming mode and the programming will
be unsuccessful. The SKREEM will also automatically exit the Customer Learn programming mode if it sees a non-blank Sentry Key transponder when
it should see a blank, if it has already programmed eight (8) valid Sentry Keys, or if the ignition switch is turned to the OFF position for more than about 
fifty seconds.

NOTE:  If an attempt is made to start the vehicle while in the Customer Learn mode (security indicator flashing), the SKIS will respond as though the
vehicle were being started with an invalid key. In other words, the engine will stall after about two seconds of operation. No faults will be set.

NOTE:  Once a Sentry Key has been programmed as a valid key to a vehicle, it cannot be programmed as a valid key for use on any other vehicle.

Keyless Entry > < Alarm System Transponder|Description and Operation