Accumulator HVAC: Service and Repair

REMOVAL

WARNING:  REVIEW THE WARNINGS AND CAUTION: IN THE FRONT OF THIS SECTION BEFORE PERFORMING THE
FOLLOWING OPERATION

1. Disconnect and isolate the negative battery cable.
2. Recover the refrigerant from the refrigerant system.
3. Remove the air filter housing to gain access to the A/C accumulator (1).
4. Disconnect the A/C suction line from the A/C accumulator and remove and discard the O-ring and gasket.
5. Remove the secondary retaining clip (2) from the spring-lock coupler that secures the accumulator inlet tube to the evaporator outlet tube (5).
6. Loosen the bolts (6) that secure the A/C accumulator to the mounting bracket (4).
7. Using the proper A/C line disconnect tool, disconnect the accumulator inlet tube from the evaporator outlet tube and remove and discard the

O-ring seals.

8. Install plugs in, or tape over the opened refrigerant system connections.
9. If required, remove the nuts (3) that secure the accumulator mounting bracket to the dash panel and remove the bracket from the engine

compartment.