Air Door Actuator / Motor: Service and Repair
Floor/Defrost Door Actuator

FLOOR/DEFROST DOOR ACTUATOR

INSTALLATION

NOTE:  This heater-A/C system is equipped with two mode door actuators. One for the floor/defrost-air door and one for the panel-air door.

1. Disconnect and isolate the negative battery cable.
2. Remove the three screws (1) that secure the floor/ defrost door actuator (2) to the driver side end of the HVAC housing (3).
3. Disconnect the HVAC wire harness connector (4) from the floor/defrost door actuator.
4. Remove the floor/defrost door actuator from the HVAC housing.

1. Position the floor/defrost door actuator (1) onto the driver side end of the HVAC housing (2). If necessary, rotate the actuator slightly to align the

splines on the actuator output shaft (3) with those on the floor/defrost door pivot shaft (4).

Actuator Blend Door|Page 5483 > < Actuator Blend Door|Page 5481