Raider V6-3.7L SOHC (2006)
5. Remove the air inlet housing from the HVAC housing and place it on a workbench.
6. Remove the three screws (1) that secure the recirculation door actuator (2) to the air inlet housing (3).
7. Remove the recirculation door actuator from the air inlet housing.
INSTALLATION
1. Position the recirculation door actuator (1) onto the air inlet housing (2). If necessary, rotate the actuator slightly to align the splines in the
recirculation-air door pivot shaft (3) with those on the actuator output shaft (4).
2. Install the three screws (1) that secure the recirculation door actuator (2) to the air inlet housing (3). Tighten the screws to 2 N.m (17 in.lbs.).