mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Actuator Blend Door|Page 5486 > < Actuator Blend Door|Page 5484
Page 2
background image

5. Remove the air inlet housing from the HVAC housing and place it on a workbench.
6. Remove the three screws (1) that secure the recirculation door actuator (2) to the air inlet housing (3).
7. Remove the recirculation door actuator from the air inlet housing.

INSTALLATION

1. Position the recirculation door actuator (1) onto the air inlet housing (2). If necessary, rotate the actuator slightly to align the splines in the

recirculation-air door pivot shaft (3) with those on the actuator output shaft (4).

2. Install the three screws (1) that secure the recirculation door actuator (2) to the air inlet housing (3). Tighten the screws to 2 N.m (17 in.lbs.).

Actuator Blend Door|Page 5486 > < Actuator Blend Door|Page 5484