Raider V6-3.7L SOHC (2006)
less than or equal to encoder-4LO-max Volts.
^
4LO SHIFT LIMIT - During Phase 2 and Phase 3 shifting, shifts may become unidirectional when a voltage is less than or equal to
encoder-4LO-min Volts has been reached.
^
4HI TARGET REGION - The position shall be considered 4HI if the voltage is greater than or equal to encoder-4HI-min Volts and it is also less
than or equal to encoder-4HI-max Volts.
^
NEUTRAL TARGET REGION - The position shall be considered NEUTRAL if the voltage is greater than or equal to encoder-Neutral-min Volts
and it is also less than or equal to encoder-Neutral-max Volts.
^
2WD TARGET REGION - The position shall be considered 2WD if the voltage is greater than or equal to encoder-2WD-min Volts and it is also
less than or equal to encoder-2WD-max Volts.
^
2WD SHIFT LIMIT - During Phase 2 and Phase 3 shifting, shifts may become unidirectional when a voltage is greater than or equal to
encoder-2WD-min Volts has been reached.
The mode sensor position will be considered invalid by the FCM if the voltage is greater than or equal to encoder_High_Range_Limit Volts or if it is
less than or equal to encoder-Low-Range Limit Volts. Refer to MODE SENSOR VOLTAGES<NV233> table for the mode sensor voltages.
MODE SENSOR VOLTAGES <NV233>