mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Automatic Transmission 42RLE|Page 3875 > < Automatic Transmission 42RLE|Page 3873
Page 4
background image

The regulator valve (9) controls hydraulic pressure in the transmission. It receives unregulated pressure from the pump (6), which works against spring
tension (8) to maintain oil at specific pressures. A system of sleeves and ports allows the regulator valve to work at one of three predetermined
pressure levels. Regulated oil pressure is also referred to as line pressure.

SOLENOID SWITCH VALVE 

The solenoid switch valve controls line pressure from the LR/CC solenoid (4). In one position, it allows the low/reverse clutch to be pressurized. In
the other, it directs line pressure to the converter control and converter clutch valves (7).

MANUAL VALVE 

Automatic Transmission 42RLE|Page 3875 > < Automatic Transmission 42RLE|Page 3873